How old is my Carrier furnace?
Find the serial number on your Carrier furnace, enter it below and get the manufacture date, its age, remaining life in seconds. Add the model number to see its size.
Carrier furnace age in short
- Date code: Week + year + plant letter (c. 1980–present).
- Example: 4808G12345 = Week 48 of 2008 (around November).
- Where to look: Rating plate sticker inside the front (blower/burner) access door: remove the front panel (Carrier: turn the panel knobs counterclockwise and pull the panel toward you).
- Model number example: 59SC5A080S17--16 = 80,000 BTU/h input.
- Typical lifespan: 12–25 years (average 18).
Updated November 2026 · How we verify
Where the serial number is on a Carrier furnace
Reading the date in a Carrier serial number
Current Carrier serials use this layout: Week + year + plant letter (c. 1980–present). Older Carrier units can use other styles — the decoder checks all 7 documented Carrier formats. Full Carrier serial number guide →
Reading a Carrier furnace model number
3 digits after the major-series letter (59SC5A080S17 → 80,000 BTU/h input). Do not confuse with the trailing '--16' (1600 cfm cooling airflow ~4 t).
Highlighted digits are the capacity code.
| Example model | What it means |
|---|---|
| 59SC5A080S17--16 | condensing gas furnace, single-stage, Comfort · 80,000 BTU/h input |
| 59SC5A100S21--20 | condensing gas furnace, single-stage · 100,000 BTU/h input |
Common Carrier furnace model prefixes:
- 58 (58SC0, 58STA, 58TP0, 58MVC, 58CVA) — non-condensing (80% AFUE) gas furnace (S/T/M = single/two-stage/modulating)
- 59 (59SC5, 59SP5, 59TP6, 59TN6, 59MN7) — condensing (90%+) gas furnace (AFUE class digit after tier)
How long does a Carrier furnace last?
A typical gas furnace lasts 12–25 years (about 18 on average). Replacing one costs roughly $3,000–$10,000 installed.
Signs your furnace is near the end:
- Age past roughly 15-20 years combined with frequent repairs
- Cracked heat exchanger (carbon monoxide risk) - generally means replacing the heat exchanger or the whole furnace
- Yellow or flickering burner flame instead of steady blue, soot around burners or flue
- Rising gas bills without a change in usage
- Uneven heating, rooms too hot or too cold
- Short cycling that persists after filter and flame-sensor service
Facing a repair? Use the repair-or-replace calculator →
Carrier furnace recalls
- 2002: CPSC, ECR International Announce Recall to Repair of Gas Boilers (Carrier, Bryant, Payne among brands)
- 2001: CPSC Announces Recall of Furnaces in California (NOx-rod furnaces; 'Sunburst by Carrier Southern California' among brands)
- 1996: CPSC and The Ducane Company Announce Recall of Upflow Horizontal Oil Furnaces (Ducane-built units incl. Carrier models)
Compare the model and serial ranges in each notice with your rating plate. All recalls: cpsc.gov/Recalls.
FAQ
How old is my Carrier furnace?
Enter the serial number from the rating plate in the decoder at the top of this page. For example, a Carrier serial like 4808G12345 means Week 48 of 2008 (around November).
Where is the serial number on a Carrier furnace?
Rating plate sticker inside the front (blower/burner) access door: remove the front panel (Carrier: turn the panel knobs counterclockwise and pull the panel toward you). Usually on the inner side wall of the cabinet or inside of the door.
How do I find the BTU rating of my Carrier furnace?
3 digits after the major-series letter (59SC5A|080|S17 -> 80,000 BTU/h input). Do not confuse with the trailing '--16' (1600 cfm cooling airflow ~4 t).
How long does a Carrier furnace last?
About 12–25 years, 18 on average. Installation quality, correct sizing and annual maintenance matter more than the brand.
Related
- Carrierall Carrier formats
- Carrier AC unitage
- Carrier heat pumpage
- Bryant furnacesame manufacturer
- Payne furnacesame manufacturer
- Heil furnacesame manufacturer
- Trane furnaceage
- Goodman furnaceage
- Lennox furnaceage
- Rheem furnaceage
- York furnaceage
- American Standard furnaceage
- Amana furnaceage
- Tempstar furnaceage