Tempstar furnace age in short
- Date code: Plant letter + year + week (c. 1990–present).
- Example: L903789847 = Week 37 of 1990 (around September).
- Where to look: Rating plate inside the front/blower access door.
- Model number example: N92ESN0401410A = 40,000 BTU/h input, 92% AFUE.
- Typical lifespan: 12–25 years (average 18).
Updated November 2026 · How we verify
Where the serial number is on a Tempstar furnace
Reading the date in a Tempstar serial number
Current Tempstar serials use this layout: Plant letter + year + week (c. 1990–present). Older Tempstar units can use other styles — the decoder checks all 5 documented Tempstar formats. Full Tempstar serial number guide →
Reading a Tempstar furnace model number
Positions 7-9 (N92ESN0401410A → 40,000 BTU/h). Then width (10-11) and cooling airflow cfm/100 (12-13). Package gas/electric: positions 7-9.
Highlighted digits are the capacity code.
| Example model | What it means |
|---|---|
| N92ESN0401410A | 92% gas furnace, fixed-speed ECM, single-stage · 40,000 BTU/h input · 92% AFUE |
| N80ESN0401412A | 80% gas furnace, single-stage · 40,000 BTU/h input · 80% AFUE |
Common Tempstar furnace model prefixes:
- N92 / N96 / F96 / G96 / R92 ... (2-3 digits = AFUE) — condensing gas furnace (brand letter F/G/N/R)
- N80 / F80 / G80 / R80 — 80% gas furnace
- N9MP / N8MP / N9MSE (older, pre-2016) — older gas furnace (e.g. N9MP2075F12A: 075 input, 12 = 1200 cfm (secondary source))
- EN / ED / EH (coils) — evaporator (furnace) coil (low confidence)
How long does a Tempstar furnace last?
A typical gas furnace lasts 12–25 years (about 18 on average). Replacing one costs roughly $3,000–$10,000 installed.
Signs your furnace is near the end:
- Age past roughly 15-20 years combined with frequent repairs
- Cracked heat exchanger (carbon monoxide risk) - generally means replacing the heat exchanger or the whole furnace
- Yellow or flickering burner flame instead of steady blue, soot around burners or flue
- Rising gas bills without a change in usage
- Uneven heating, rooms too hot or too cold
- Short cycling that persists after filter and flame-sensor service
Facing a repair? Use the repair-or-replace calculator →
Tempstar furnace recalls
Compare the model and serial ranges in each notice with your rating plate. All recalls: cpsc.gov/Recalls.
FAQ
How old is my Tempstar furnace?
Enter the serial number from the rating plate in the decoder at the top of this page. For example, a Tempstar serial like L903789847 means Week 37 of 1990 (around September).
Where is the serial number on a Tempstar furnace?
Rating plate inside the front/blower access door.
How do I find the BTU rating of my Tempstar furnace?
Positions 7-9 (N92ESN|040|1410A -> 40,000 BTU/h). Then width (10-11) and cooling airflow cfm/100 (12-13). Package gas/electric: positions 7-9.
How long does a Tempstar furnace last?
About 12–25 years, 18 on average. Installation quality, correct sizing and annual maintenance matter more than the brand.